Description
Feature
- High Sensitivity, quick response, and long sensor lifetime
- Automatic and manual mode suitable for locating leaks in various complex environments.
- The new suction structure design increases the sensitivity while having the anti-water absorption function at the same time.
- Compliant to SAE J 1627, EN 14624, CE
Specification
- Sensor type: Heated diode gas sensor
- Minimum detectable leakage: ≤3 g/year
- Reaction time: ≤3 seconds
- Warm-up time: 30 seconds
- Reset time: ≤10 seconds
- Operating temperature range: 0-50℃
- Operating humidity range: <80%RH(non-condensing)
- Applicable refrigerant: CFCs, HCFCs, HFCs, HCs and HFOs
- Sensor lifetime: ≥1 year
- Reset: Automatic/manual
- Probe length: 420mm(16.5in)
- Battery life: 7 hours
Package includes
- LD-100+ leak detector (excluding sensor) x 1
- Heated diode gas sensor x 1
- User manual x 1
- Calibration certificate x 1